CTS Temperature Shock Test Chamber TSS-70/130 Hot: +50°C to +200°C Cold: -80°C to +100°C 130LCTS
TSS-70/130
CTS Temperature Shock Test Chamber TSS-70/130 Hot: +50°C to +200°C Cold: -80°C to +100°C 130L
CTS
TSS-70/130
État
Occasion
Emplacement
Borken 

Données de base
- Désignation de la machine:
- CTS Temperature Shock Test Chamber TSS-70/130 Hot: +50°C to +200°C Cold: -80°C to +100°C 130L
- Fabricant:
- CTS
- Modèle:
- TSS-70/130
- État:
- d'occasion
Prix et localisation
- Emplacement:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Appel
Détails sur l'offre
- Identifiant de l'annonce:
- A21799033
- Numéro de référence:
- 25161
- Mise à jour:
- dernière mise à jour le 15.10.2026
Description
CTS
Type: TSS-70/130
Water-cooled cooling unit
For sale is a high-quality temperature shock test chamber from CTS
(Clima Temperatur Systeme), model TSS-70/130.
The device is used for performing temperature shock tests
and is typically used in industry, research, and quality assurance.
Application areas:
Material tests
Aging tests
Electronics and component tests
Temperature shock and cyclic temperature tests
Technical data:
Type: TSS-70/130
Bjdoy Hkd Hspfx Acyeww
Test volume: 130 liters
Temperature range:
Hot chamber: +50°C to +200°C
Cold chamber: -80°C to +100°C
Heating rate: approx. 6 K/min from room temperature to +180°C
Cooling rate: approx. 4 K/min from room temperature to -60°C
Temperature deviation:
±1 K in time
±2 K spatially
Temperature change rate:
max. 100 K/min on average for shock test tests
without heat input
Temperature adjustment rate:
≤ 15 min in the range of -65°C to +200°C
with 10 kg of ICs
Cycle time:
< 10 seconds
Electrical data:
Connection: 400 V, 3/N, 50 Hz
Rated power: approx. 17.2 kW
Rated current: approx. 29 A
On-site protection: 32 A slow-blow fuse
Connection: Cekon 32
Refrigeration system:
Refrigerant: R404A / R23
water-cooled, low-noise, fully hermetic
Equipment / Features:
CTS control panel
Microprocessor-controlled control and monitoring system
Program operation
up to 100 test programs possible
digital setpoint and actual value display
RS232 interface
2 free switching channels for on-site control of the test specimen
Fault message on potential-free contact
Load up to 30 V DC, 2 A
EMC tested
Technical design:
Hot and cold chamber
Mobile frame with lifting spindle drive
Test chamber / mobile frame made of stainless steel, material no. 1.4301
Insert basket made of stainless steel wire
Pipe passage NW 50 with sealing plug
Compressed air connection 1/4" AG
Condensate drain non-pressurized R 1/2" internal thread
Safety door lock
lockable door with window
Dimensions according to installation diagram:
External dimensions approx.: 2335 x 940 x 1820 mm
Loading dimension approx.: 1990 x 940 x 1652 mm
Test chamber dimensions: height approx. 410 mm
Width approx. 480 mm, depth approx. 660 mm
Window: 300 x 300 mm
Other data:
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 950 kg
Average consumption during test cycle: approx. 8 kWh
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: see pictures
(Changes and errors in technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
L'annonce a été traduite automatiquement et des erreurs de traduction peuvent apparaître.
Type: TSS-70/130
Water-cooled cooling unit
For sale is a high-quality temperature shock test chamber from CTS
(Clima Temperatur Systeme), model TSS-70/130.
The device is used for performing temperature shock tests
and is typically used in industry, research, and quality assurance.
Application areas:
Material tests
Aging tests
Electronics and component tests
Temperature shock and cyclic temperature tests
Technical data:
Type: TSS-70/130
Bjdoy Hkd Hspfx Acyeww
Test volume: 130 liters
Temperature range:
Hot chamber: +50°C to +200°C
Cold chamber: -80°C to +100°C
Heating rate: approx. 6 K/min from room temperature to +180°C
Cooling rate: approx. 4 K/min from room temperature to -60°C
Temperature deviation:
±1 K in time
±2 K spatially
Temperature change rate:
max. 100 K/min on average for shock test tests
without heat input
Temperature adjustment rate:
≤ 15 min in the range of -65°C to +200°C
with 10 kg of ICs
Cycle time:
< 10 seconds
Electrical data:
Connection: 400 V, 3/N, 50 Hz
Rated power: approx. 17.2 kW
Rated current: approx. 29 A
On-site protection: 32 A slow-blow fuse
Connection: Cekon 32
Refrigeration system:
Refrigerant: R404A / R23
water-cooled, low-noise, fully hermetic
Equipment / Features:
CTS control panel
Microprocessor-controlled control and monitoring system
Program operation
up to 100 test programs possible
digital setpoint and actual value display
RS232 interface
2 free switching channels for on-site control of the test specimen
Fault message on potential-free contact
Load up to 30 V DC, 2 A
EMC tested
Technical design:
Hot and cold chamber
Mobile frame with lifting spindle drive
Test chamber / mobile frame made of stainless steel, material no. 1.4301
Insert basket made of stainless steel wire
Pipe passage NW 50 with sealing plug
Compressed air connection 1/4" AG
Condensate drain non-pressurized R 1/2" internal thread
Safety door lock
lockable door with window
Dimensions according to installation diagram:
External dimensions approx.: 2335 x 940 x 1820 mm
Loading dimension approx.: 1990 x 940 x 1652 mm
Test chamber dimensions: height approx. 410 mm
Width approx. 480 mm, depth approx. 660 mm
Window: 300 x 300 mm
Other data:
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 950 kg
Average consumption during test cycle: approx. 8 kWh
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: see pictures
(Changes and errors in technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
L'annonce a été traduite automatiquement et des erreurs de traduction peuvent apparaître.
Envoyer une demande
Téléphone & Fax
+49 2861 ... afficher
Ces annonces pourraient également vous intéresser.
Réussite :
Votre message a été envoyé.
Annonce
Borken
226 km
Armoire d’essai de choc thermique CTS TSS-70/130 -80°C à +200°C 130 litres, refroidissement par eau
CTSTSS-70/130
CTSTSS-70/130
Réussite :
Votre message a été envoyé.
Annonce
Borken
226 km
Armoire de test de température CTS TS-70/200-5/S 200L -70°C à +180°C
CTSTestkammer TS -70/200-5
CTSTestkammer TS -70/200-5
Votre annonce a été supprimée
Une erreur est survenue